Low-temperature bolting
Define the toughness required of studs, bolts and nuts at the temperature specified for your cryogenic equipment.
Manufacturer case study
Grade 660D for an FLNG conversion
An engineering customer specified a minimum Charpy impact energy of 70 J at −196°C for Grade 660D stud bolts and hex nuts. CSA reported preliminary material samples that met that target. Finished-part validation and independent testing were still planned at the time of its report.
Read the CSA Group case ↗What to send
- Service and test temperatures
- Give the minimum service temperature and the required impact-test temperature separately, with units.
- Impact acceptance
- Copy the specified energy, specimen size and any individual or average acceptance limits from the project specification.
- Lot documentation
- Identify the grade, part diameter, drawing revision, lot sampling and any third-party witness requirement.
Request a drawing review